Skip to main content

FlamePRO Chemical Formulation

Industry-leading Class A Fire Retardant Chemical Formulation

Our industry-leading Class A fire retardant chemical formulation is designed to reduce flame spread and smoke development and is used primarily in commercial applications per the model building codes.

FlamePRO Chemical Treated wood

Overview

Our industry-leading Class A fire retardant chemical formulation is designed to reduce flame spread and smoke development and is used primarily in commercial applications per the model building codes. Flame Pro chemical formulations are used only in commercial grade pressure wood treating environments. Fire retardant chemicals are used in the manufacturing of treated wood products and are used by approved manufacturers that treat under Koppers Performance Chemicals standards, the industry standards, and are monitored by third party inspection. Koppers Performance Chemical only produces Class A fire retardant products. FlamePro chemical formulation is listed as FR-2 by the AWPA and can be found in the AWPA standards.

All FlamePRO® is required to be Kiln Dried After Treatment (KDAT) back to the fibers original moisture content, 19% for lumber and 15% for plywood.

FlamePro® formulation is monitored by Underwriters Laboratories (UL) and FlamePro® FRT wood bears an ICC ESR report (ESR-4244) confirming it meets the model building codes for Division 6 Rough Carpentry.

A 50-Year Limited Warranty against structural failure due to heat or humidity is available. See warranty for details.

Features & Benefits

  • Meets all major model building code requirements, as described in the ICC Evaluation Services, Inc.ESR-4244
  • Pressure TreatedNot a Paint or Coating
  • The majority of common lumber and plywood species used in building construction can be treated with FlamePRO®.
  • Backed by a 50 Year Limited Warranty Program from Koppers Performance Chemicals Inc.
  • Independently Tested & Quality Monitored by Independent Inspection Agency
  • Optional orange color indicator for building site recognition.
  • Highly Cost Effective
  • Low corrosion rates to code-approved metal fasteners and hardware.
  • Low Hygroscopicity
  • Low Smoke Development Values and Low Flamespread Index Values. UL Classified with an FR-S Rating for flame spread and smoke development values of 25 or less.
  • Superior Strength DurabilitySTM E84 Extended 30-minute Test ASTM E119 1 & 2 Hour Wall Assemblies

Applications

  • Interior Use

Wood treated with FlamePRO® chemical formulation is typically specified for use in interior areas not exposed to the weather or wetting and where the adopted building code permits the use of wood or fire retardant treated wood.

General Use - Interior

Only used in interior, enclosed, dry applications not exposed to dampness or wetting such as: Roof Trusses, Rafters, Plywood Roof Sheathing, Floor & Roof Joists, Mezzanines, Sill Plates, Shelving, Steps, Stairways, Studs, Interior Partitions (Non-load), Floor Sheathing, Plywood Subflooring, Partition Walls, Beams & Purlins, Blocking & furring, Platforms, Stages, Wall Sheathing & Paneling, Architectural, Millwork & Trim, Backing for Electrical Panels, 1 & 2 Hour Wall Assemblies

Specifications & Certifications

Wood treated with FlamePRO® chemical formulation products comply with AWPA UC-1 and UCFA use category systems, FlamePro® treatment process meets the AWPA T1 standard and FlamePro® chemical has been analyzed to confirm the formulation meets AWPA P50 standard. The FlamePRO® proprietary ingredients are American Wood Protection Association (AWPA) Standardized for UCFA Fire Retardant Interior applications.

Architectural Specifications & Building Code Approvals

Wood treated with FlamePRO® chemical formulation, as described in the ICC Evaluation Services, Inc. ESR-4244, meet all major model building code requirements.

  • FlamePRO® shall be produced in accordance with International Code Council (ICC) Evaluation Service Report (ESR) ESR-4244.
  • Wood treated with FlamePRO® chemical formulation comply with AWPA UC-1 and UCFA use category systems, FlamePro® treatment process meets the AWPA T1 standard and FlamePro® chemical has been analyzed to confirm the formulation meets AWPA P50 standard.

International Building Code Compliant (Section 2303.2)

The code language is clear. Surface applied fire retardant products for wood are not equivalent to pressure impregnated Fire Retardant Treated Wood. Surface applied products, whether factory applied or site applied, simply don’t provide adequate protection and ARE NOT appropriate for use where Fire Retardant Treated Wood is required.

FlamePRO® chemical formulation is applied via pressure impregnation, fully code compliant Fire Retardant Treated Wood. It is appropriate for use in all applications where Fire Retardant Treated Wood is required.

Testing and Standards

Standards

  • Wood treated with FlamePRO® chemical formulation comply with AWPA UC-1 and UCFA use category systems, FlamePRO® treatment process meets the AWPA T1 standard.
  • 1 Hour and 2 Hour Tested Interior Wall Assembly, and 2 Hour Tested Exterior Wall Assembly (ASTM E119).
  • Hygroscopicity testing conducted by a third party independent laboratory has confirmed that compared to untreated wood, FlamePRO® brand fire retardant treated wood does not pick up excessive moisture under ASTM D3201 test conditions.

Testing

  • UL 723 — Surface Burning Characteristics
  • ASTM E84 — Surface Burning Characteristics
  • ASTM 2768 — Extended 30-minute Test
  • ASTM E119 — Fire Tests of Building Construction
  • ASTM D3201 — Hygroscopic Properties
  • ASTM D5516 — Flexural Properties Plywood
  • ASTMM D5664 — Flexural Properties Lumber
  • ASTM D6305 — Strength Design
  • ASTM D6841 — Treatment Adjustment Factors
  • AWPA E12 — Determining Corrosion of Metal
  • AWPA M4 — Care of Treated Wood
  • AWPA P50 — Standard for Fire Retardants
  • AWPA T1 — Treatment Standard

Copies of tests are available to design professionals upon request.

For a complete specification, contact us or call Koppers Performance Chemicals Inc. at 800-585-5161.

Certifications

  • ICC ESWood treated with FlamePRO® chemical formulation, as described in the ICC Evaluation Services, Inc. ESR-4244, meet all major model building code requirements.
  • UL ClassifiedUL Classified with an FR-S Rating for flame spread and smoke development values of 25 or less.
  • AWPA StandardizedPressure treated wood products comply with AWPA UC-1 and UCFA use category systems, FlamePRO® treatment process meets the AWPA T1 standard.
  • Indoor Advantage™ Gold CertifiedSCS Global Services has completed the evaluation of Koppers’ FlamePRO® Treated Lumber products. Koppers FlamePRO® Fire Retardant Treated Wood products meet all the necessary requirements to be certified Indoor Advantage™ Gold.
  • UL GREENGUARD GOLD CertifiedGREENGUARD GOLD Certification indicates that FlamePRO® products have undergone rigorous testing and have met stringent standards for low volatile organic compound (VOC) emissions. Products certified to this criteria are suitable for use in schools, offices, and other sensitive environments.
  • Cal Fire CertifiedCAL FIRE is responsible for providing wildland fire protection and resource management on over 31 million acres of State Responsibility Area (SRA) lands throughout California.

Care & Usage

Wood treated with FlamePRO® chemical formulation Fasteners and Hardware Information

The corrosivity of wood treated with FlamePRO® chemical formulation has been evaluated in accordance with AWPA Standard E12 for a variety of metals.

The corrosion rates for carbon steel, galvanized steel, aluminum, red brass, and copper are not significantly increased by FlamePRO® fire retardant chemicals when the treated wood products are used as recommended by the manufacturer and properly sized for the materials selected.

Corrosion testing indicates excellent performance even with non-galvanized carbon steel fasteners. It is still recommended that galvanized fasteners be used just as galvanized truss plates are used on untreated wood trusses. The same galvanized truss plates are acceptable for use with FlamePRO® lumber, as are plated galvanized nails and screws.

The FlamePRO® chemical formulation does not cause fasteners to corrode. The treating industry recommends the use of hot dip galvanized or stainless steel fasteners for all types of treated wood due to exposure to the weather.

More Information on Fasteners & Hardware Usage on wood treated with FlamePRO® chemical formulation.

Care and Maintenance

Under normal temperature and humidity conditions, latex and oil-based paints, as well as water- and solvent-based stains, can be used with wood treated with FlamePRO® chemical formulation.

If prolonged exposure to high humidity conditions is expected, special surface preparation procedures including the use of an appropriate primer are recommended.

Important Information

The following precautions should be taken both when handling wood treated with FlamePRO® chemical formulation.

  • Guidelines for use, handling and disposing of treated wood products contain compliance information required by the California Department of Toxic Substances Control.
  • Wood treated with FlamePRO® chemical formulation used in structural applications shall be installed in accordance with the conditions and limitations listed in ICC ESR-4244.
  • Wood treated with FlamePRO® chemical formulation shall be installed in compliance with the requirements of the applicable building codes and product recommendations.
  • Some fire retardant treated wood chemicals may migrate from the treated wood into soil/water or may dislodge from the treated wood surface upon contact with skin. Wash exposed skin areas thoroughly.
  • Projects should be designed and installed in accordance with federal, state, and local building codes and ordinances governing construction in your area and in accordance with the National Design Specifications (NDS) and the Wood Handbook.
  • Mold growth can and does occur on the surface of many products, including untreated and fire retardant treated wood, during prolonged surface exposure to excessive moisture conditions. To remove mold from the treated wood surface, wood should be allowed to dry. Typically, mild soap and water can be used to remove remaining surface mold. For more information visit www.epa.gov
  • Use fire retardant treated wood safely. Always read the label and product information before use.
  • DISCLAIMER OF LIABILITY FOR RELIANCE ON INFORMATION PROVIDED BY KOPPERS PERFORMANCE CHEMICALS: The information contained herein is true and accurate to the best of our knowledge, but is provided without warranty or guarantee. Since the conditions of use are beyond our control, Koppers Performance Chemicals (“Koppers”) disclaims all liability and assumes no legal responsibility for damages resulting from use of or reliance upon the information contained herein.

Resources

Frequently Asked Questions

This chemical formulation can only be used by licensed manufacturers/commercial wood treaters that treat under Koppers Performance Chemicals, the industry and are monitored by third party inspection.

ALL OTHER FAQS BELOW, COPIED FROM FLAMEPRO FRTW

Need help?

Not sure which treatment fits your specific industry, application, or end-use? Reach out to our team of experts to discuss your project needs.